Files
bootloader/test/test_scan.py
BlackMark 7716e1e291 audit: the port's pass — the scan that could not walk, and the drift a generator ends
--scan's walk was unwalkable on POSIX: probe rates have no termios
B-constant, so the first off-nominal probe raised out of the loop. The port
speaks termios2 BOTHER now (red-proven on a pty at 9984 Bd), the probe's
open lives inside the walk's error handling, an fd no longer leaks on an
unmakeable rate, and the swallowed unknown-signature reply is named at
timeout instead of reported as silence. CMakePresets.json's generator emits
the submodule toolchain path it had drifted from — a hand edit on a
generated file, exactly the class rule 10 exists for — and presets.generated
gates the pair from here on (the  marker CMake rejects at the
presets root stayed out; the check is the guard). The over-slot image guard
the tsb runner gained reaches the pureboot runner too; the GPIO bridge's
delivery comment states the hardware truth (RXC at the stop bit's sampling
point); the hardware suite gains the scan check — the one place the rate
physics is real; and the libavr pin advances over both audit rounds.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-28 10:12:17 +02:00

72 lines
2.4 KiB
Python

#!/usr/bin/env python3
"""--scan's walk and report logic, no simulator: the probe order, the rate
arithmetic, and the advice's direction. The rate physics itself is not
sim-testable — a pty carries bytes at any termios rate — so what the wire
would arbitrate is pinned here as logic instead.
Usage: test_scan.py <tool_py>
"""
import os
import sys
def fail(message):
print(f"FAIL: {message}")
sys.exit(1)
def main():
sys.path.insert(0, os.path.dirname(os.path.abspath(sys.argv[1])))
import pureboot as pb
walk = pb.scan_ratios()
if walk != [0, -2, 2, -4, 4, -6, 6, -8, 8, -10, 10]:
fail(f"probe walk is not built-rate-first, nearest-out: {walk}")
if pb.scan_rate(9600, 4) != 9984 or pb.scan_rate(9600, -4) != 9216:
fail("probe rate arithmetic")
if pb.scan_rate(115200, 0) != 115200:
fail("the built rate must probe unchanged")
# A loader answering fast means a fast oscillator: the trim goes down.
report = "\n".join(pb.scan_report(9600, 4, 6))
for needle in ("9984", "+4 %", "--baud 9984", "4 steps lower", "pureboot 6"):
if needle not in report:
fail(f"+4 % report lacks {needle!r}:\n{report}")
report = "\n".join(pb.scan_report(9600, -6, 6))
if "6 steps higher" not in report:
fail(f"-6 % report advises the wrong direction:\n{report}")
report = "\n".join(pb.scan_report(9600, 0, 6))
if "none" not in report or "steps" in report:
fail(f"an on-rate answer must advise no trim:\n{report}")
report = "\n".join(pb.scan_report(9600, 4, 6, clock=9600000))
if "9984000" not in report:
fail(f"the absolute clock must scale with the found ratio:\n{report}")
# The walk's rates mostly have no termios B-constant, so the POSIX port
# must set them through termios2 — probed on a pty, which accepts the
# ioctl without caring about the speed. Without this every off-nominal
# probe would abort the walk on the platform --scan matters most on.
if os.name == "posix":
import pty
master, slave = pty.openpty()
try:
port = pb.Port(os.ttyname(slave), pb.scan_rate(9600, 4))
port.set_baud(pb.scan_rate(9600, -4))
port.close()
except pb.Error as error:
fail(f"PosixPort refused an off-nominal probe rate: {error}")
finally:
os.close(master)
os.close(slave)
print("OK")
if __name__ == "__main__":
main()