pbhw: --one-wire never reached the suite's own sessions
The flag was plumbed through pbrig.Deployment to the host-tool subprocess calls and nowhere else, so identity() and scan() opened a raw port and drove a shared line as though it were two wires. On real one-wire hardware the adapter's echo answers the knock before the device does, so the suite would have died at its very first check — "the loader never answered; nothing below can be trusted" — for the one deployment the flag exists to test, and every result after it is gated on that check passing. Both now open through pbrig.Rig.open_port(), which applies the deployment's link mode. The gap underneath was that only the subprocess path could reach those facts at all; anything driving the protocol in-process had to restate them, and did not. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
@@ -53,7 +53,7 @@ class Suite:
|
|||||||
"""The info block, which every later check takes its bounds from."""
|
"""The info block, which every later check takes its bounds from."""
|
||||||
module = pbrig.load_pureboot(self.rig.d.pureboot)
|
module = pbrig.load_pureboot(self.rig.d.pureboot)
|
||||||
self.rig.reset()
|
self.rig.reset()
|
||||||
port = module.Port(self.rig.d.port, self.rig.d.baud)
|
port = self.rig.open_port() # wrapped for the echo where the line is shared
|
||||||
try:
|
try:
|
||||||
loader = module.Loader(port)
|
loader = module.Loader(port)
|
||||||
if self.rig.d.autobaud:
|
if self.rig.d.autobaud:
|
||||||
@@ -87,7 +87,10 @@ class Suite:
|
|||||||
rate = module.scan_rate(self.rig.d.baud, pct)
|
rate = module.scan_rate(self.rig.d.baud, pct)
|
||||||
self.rig.reset()
|
self.rig.reset()
|
||||||
try:
|
try:
|
||||||
port = module.Port(self.rig.d.port, rate)
|
# Same wrap as identity(): on a shared line an undiscarded
|
||||||
|
# echo answers every rate a scan probes, so the walk would
|
||||||
|
# report the first one it tried.
|
||||||
|
port = self.rig.open_port(rate)
|
||||||
except module.Error as error:
|
except module.Error as error:
|
||||||
self.check("scan opens every probe rate", False, f"{rate} Bd: {error}")
|
self.check("scan opens every probe rate", False, f"{rate} Bd: {error}")
|
||||||
return
|
return
|
||||||
|
|||||||
@@ -281,6 +281,22 @@ class Rig:
|
|||||||
return 99, f"TIMEOUT after {timeout}s\n{expired.stdout or ''}{expired.stderr or ''}"
|
return 99, f"TIMEOUT after {timeout}s\n{expired.stdout or ''}{expired.stderr or ''}"
|
||||||
return result.returncode, (result.stdout or "") + (result.stderr or "")
|
return result.returncode, (result.stdout or "") + (result.stderr or "")
|
||||||
|
|
||||||
|
def open_port(self, baud: int | None = None):
|
||||||
|
"""A port opened the way this deployment says to speak to the board.
|
||||||
|
|
||||||
|
Everything the rig runs as a *subprocess* gets its flags from
|
||||||
|
`pureboot()` above; anything that drives the protocol in-process has
|
||||||
|
to reach the same facts, and until this existed only the subprocess
|
||||||
|
path could. A shared line is the one where that gap is fatal rather
|
||||||
|
than untidy: the host reads back every byte it writes, so an
|
||||||
|
undiscarded echo answers the knock before the device does. Open
|
||||||
|
through here and a one-wire deployment cannot be silently driven as
|
||||||
|
a two-wire one.
|
||||||
|
"""
|
||||||
|
module = load_pureboot(self.d.pureboot)
|
||||||
|
port = module.Port(self.d.port, self.d.baud if baud is None else baud)
|
||||||
|
return module.OneWirePort(port) if self.d.one_wire else port
|
||||||
|
|
||||||
def capture(self, seconds: float = 2.0, baud: int | None = None) -> bytes:
|
def capture(self, seconds: float = 2.0, baud: int | None = None) -> bytes:
|
||||||
"""Listen to whatever the board is saying, at an arbitrary rate.
|
"""Listen to whatever the board is saying, at an arbitrary rate.
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue